DST100

Temperature transmitter with display, programmable by NFC/RFID technology


 

DST100 series integrates process reading and visualization with analogue retransmission of temperature value, allowing also to manage two activation thresholds by means of two PNP outputs. 

 

This transmitters stands out in its product segment thanks to innovative and unique features: programming by NFC/RFID technology, independent rotation of display and electrical connector, selection of the analogue output by parameter as mA or Volt, scalability of measuring range of the nominal scale, integrated datalogger with programmable sampling time. 

 

MyPixsys App - same as already in use for Pixsys signal converters and STR indicators - allows quick programming by Android smartphones without wirings and particularly useful for on site updates. 

Ordering codes

2000.01.002
DST100 - Range -50°+150°C / Fixed connection - 1/2”GAS EL = 100 mm
2000.01.003
DST100 - Range -50°+150°C / Fixed connection - 1/2”GAS EL = 150 mm
2000.15.002
DST100 - Range -50°+150°C / Sliding connection - 1/4” NPT EL = 100 mm
2000.15.003
DST100 - Range -50°+150°C / Sliding connection - 1/4” NPT EL = 150 mm
2000.93.002
DST100 - Range -50°+150°C / Clamp connection - C50 EL = 100 mm
2000.96.002
DST100 - Range -50°+150°C / Food connection - DN50 EL = 100 mm

Main features

Box
93 x 37 mm
Power supply
15..30 VDC
Power consumption
Max 0,8 W
Operating conditions
Temperature -25..+85 °C, humidity 35..95 RH%
Material
Sensor housing steel AI316, display housing plastic
Weight
Approx. 189 g
Sealing
IP67 - FPM, NBR, EPDM

Technical data

Measuring range
- 50..150 °C
Sensor type
PT1000
Pressure connection
1/2'' GAS; 1/4'' NPT; C50 (Clamp); DN50 (Food)
Electrical connection
EN175301-803-A (DIN43650-A); M12x1 5 Pole
Housing orientation
Display 335° rotatable - Electrical connection 343° rotatable
Sensor working temperature
- 25..+ 85°C
Accuracy
± 0,2% F.S. @25°C

Software features

Digital output
N.2 outputs PNP
Analogue output
Programmable by parameter as mA or V
Display
4 Digit 1..3 decimal points
Pressure unit
Selectable °C, °F, °K
Datalogger
Ring buffer: 3518 data points - Sampling time: 0.1 ... 999.9 s, Off (0)
Quick set-up options
Programming via MyPixsys APP for Android smartphones (NFC)

User Manual - Video - Application Notes - Datasheet

User manual EN
30/07/2018
English
PDF

Installation

<p>Dimensioni e installazione regolatore dst400</p>