ALERT! Spoofing and fake emails concerning payments – read carefully!

Pixsys
  • Products
    • Controllers - Indicators
      • Entry level
      • Advanced
      • DIN rail
      • Indicators - Panel meters
    • Timers - Counters
    • Process controllers
    • Programmable logics
      • HMI CODESYS
      • PLC
      • HMI + Soft PLC LogicLab
    • I/O Modules
      • Plug-in I/O
      • Remote I/O
    • Operator Panels
      • HMI
      • Web Panel
      • Panel PC
    • Converters - Gateways
      • Signal converters
      • Serial /Protocol converters
      • Modem IIoT
      • VPN Gateway
    • Network Analyzers
      • Current transformer
      • Single-phase network analyzer
      • Three-phase network analyzer
    • Sensors
      • Temperature sensors
      • Infrared sensors
      • Pressure transmitters
      • MELT Pressure transducers
      • Humidity transmitters
    • Actuators
      • SSR
      • Inverters
    • Software and solutions
      • MyPixsys App
      • Programming software Controllers/Indicators
      • CODESYS
      • PLC LogicLab tool
      • HMI Movicon graphics tool
      • Monitoring/recording software
    • General
      • End-of-Life products
      • Discontinued products
      • Accessories
  • Applications
  • Pixsys
  • News
  • Support
  • Contacts
  • Reserved Area
Search in:
    • English
    • Italiano
    English
    • Home
    •   /  
    • En
    •   /  
    • Converters gateways
    •   /  
    • Protocol converters
    •   /  
    • Cnv510

    CNV510 | Protocol converter

    Pixsys CNV510 protocol converters enable communication between networks relying on different  protocols. CNV510 allow to interface devices equipped with Modbus RTU protocol on RS485 or CANOpen with systems based on the Siemens ProfibusDP and Profinet protocols.

    Specifically CNV510 models equipped with serial port RS485 allow to integrate Pixsys controllers, I/O modules, PLCs and HMIs into existing or new Siemens networks.

    The programming software of the converters  allows to create automatically the configuration in .GSD file format to integrate Pixsys devices into Siemens development environments TiA Portal and Step7.
     

    Request Information →

    Request Information

    ×

    • Data sheet
    • Disegno meccanico dxf
    • Man. Inst. EN CNV510-PBUS-RTU
    • Man. Inst. EN CNV510-PNET-RTU
    • SW - CNV510-PBUS-RTU
    • SW - CNV510-PBUS-CAN
    • SW - CNV510-PNET-RTU
    • SW - CNV510-PNET-CAN
    • SW - CNV510-PNETSL-ETHM-A
    • SW - CNV510-TCP-PBUS-A
    to unlock downloads ACCEPT COOKIES
    • Dimensions
      71 x 90 x 64 mm - 4 modules DIN43880
    • Material
      Noryl V0
    • Weight
      Approx. 250 g
    • Sealing
      Box and terminal blocks: IP20
    • Operating conditions
      Temperature 0..45 °C, humidity 35..95 RH%
    • Certifications
      CE

    ORDERING CODES

    CNV510-PBUS-RTU-A

    CNV510-PBUS-CAN-A

    CNV510-PNET-RTU-A

    CNV510-PNET-CAN-A

    Power supply

    12..24 V DC ±15%

    12..24 V DC ±15%

    12..24 V DC ±15%

    12..24 V DC ±15%

    Power consumption

    3 Watt/VA

    3 Watt/VA

    3 Watt/VA

    3 Watt/VA

    Reading memory

    512 Bytes

    512 Bytes

    512 Bytes

    512 Bytes

    Writing memory

    512 Bytes

    512 Bytes

    512 Bytes

    512 Bytes

    Serial communication

    1x RS485 (1200..115200 Baud) galvanically isolated

    -

    1x RS485 (1200..115200 Baud) galvanically isolated

    -

    CAN

    -

    1x CAN (50K..1Mbit) galvanically isolated

    -

    1x CAN (50K..1Mbit) galvanically isolated

    Ethernet

    1x 10 / 100 Mbit/s

    1x 10 / 100 Mbit/s

    1x 10 / 100 Mbit/s

    1x 10 / 100 Mbit/s

    • Communication protocol Profibus
      Profibus Slave (codes -PBUS) with file .gsd
    • Communication protocol PROFINET
      PROFINET Slave (codes-PNET) with file .gsd
    • Communication protocol CAN Open
      CAN Open Master (codes -CAN) with file .esd
    • Communication protocol Modbus RTU
      Modbus RTU Slave (codes -RTU)
    CNV_dis_CNV_series
    • CNV510-PBUS-RTU-A
      PROFIBUS -> MODBUS (RS485) CONVERTER
      link locator link pixsys
    • CNV510-PBUS-CAN-A
      PROFIBUS -> CANOPEN CONVERTER
      link locator link pixsys
    • CNV510-PNET-RTU-A
      PROFINET -> MODBUS (RS485) CONVERTER
      link locator link pixsys
    • CNV510-PNET-CAN-A
      PROFINET -> CANOPEN CONVERTER
      link locator link pixsys
    Discover Related Products:
    ATR224 | 48x48mm PID Controller

    ATR224 | 48x48mm PID Controller

    Discover
    MCM260X | Remote I/O  CANopen - Modbus

    MCM260X | Remote I/O CANopen - Modbus

    Discover
    TD710 HMI  7

    TD710 HMI 7"

    Discover
    pixsys

    Via Po, 16
    30030 - Mellaredo di Pianiga (VE)
    Italy
    Ph. +39 041 5190518 
    Mail: info@pixsys.net

    • COMPANY

      • About us
      • News
      • Applications
    • SUPPORT

      • Real time support
      • Technical FORUM
      • Video tutorials
    Privacy Policy Contacts
    REA PD 362721 - VAT no. IT04111740280 - Suppliers PEC: pixsyssrl_fornitori@pec.it
    Copyright © Pixsys 2025. All Rights Reserved.
    Back to top
    Iris _