ALERT! Spoofing and fake emails concerning payments – read carefully!

Pixsys
  • Products
    • Controllers - Indicators
      • Entry level
      • Advanced
      • DIN rail
      • Indicators - Panel meters
    • Timers - Counters
    • Process controllers
    • Programmable logics
      • HMI CODESYS
      • PLC
      • HMI + Soft PLC LogicLab
    • I/O Modules
      • Plug-in I/O
      • Remote I/O
    • Operator Panels
      • HMI
      • Web Panel
      • Panel PC
    • Converters - Gateways
      • Signal converters
      • Serial /Protocol converters
      • Modem IIoT
      • VPN Gateway
    • Network Analyzers
      • Current transformer
      • Single-phase network analyzer
      • Three-phase network analyzer
    • Sensors
      • Temperature sensors
      • Infrared sensors
      • Pressure transmitters
      • MELT Pressure transducers
      • Humidity transmitters
    • Actuators
      • SSR
      • Inverters
    • Software and solutions
      • MyPixsys App
      • Programming software Controllers/Indicators
      • CODESYS
      • PLC LogicLab tool
      • HMI Movicon graphics tool
      • Monitoring/recording software
    • General
      • End-of-Life products
      • Discontinued products
      • Accessories
  • Applications
  • Pixsys
  • News
  • Support
  • Contacts
  • Reserved Area
Search in:
    • English
    • Italiano
    English
    • Home
    •   /  
    • En
    •   /  
    • Process controllers cycle programmers
    •   /  
    • Atr264

    ATR264 | Programmer 48x48mm

    ATR264 is a programmer dedicated to the automation of small industrial ovens or laboratory ovens, dryers, heat treatment systems, and in general the management of a process involving cycles/profiles with control of the process variable in relation to time. 


     ATR264 allows the programming of 15 cycles/profiles, each one including up to 30 steps/segments, all free configurable by the user as ramp/soak/cooling.


    The device integrates  software functions typically required in oven/furnace management: Waiting (in the case the process is delayed in comparison to programmed setpoint) and Cycle Recovery mode (after any power failure). Special function for gas kilns management are available (code -13ABC).


    Like other Pixsys programmers, ATR264 stands out for user-friendly interface and programming mode even for inexperienced operators. 

    Parameter configuration and cycle programming is possible via MyPixsys App on  smartphone thanks to NFC/Rfid technology or on PC with MyPixsysLab software  as well as directly from keyboard.


    Request Information →

    Request Information

    ×

    • Installation manual
    • MyPixsysLab v.1.25
    to unlock downloads ACCEPT COOKIES
    • Dimensions
      48 x 48 x 80mm
    • Material
      Box: PC UL94V2 self-extinguishing, front panel: PC UL94V2
    • Weight
      Approx. 185 g
    • Sealing
      Front panel: IP65, Box and terminal blocks: IP20
    • Operating conditions
      Temperature 0-45 °C, humidity 35..95 RH%
    • Certifications
      CE, UL (-12ABC-T only)

    ORDERING CODES

    ATR264-12ABC-T

    ATR264-13ABC

    Power supply

    24...230 V AC / DC ±15% 50/60 Hz - galvanic isolation 2,5KV

    24...230 V AC / DC ±15% 50/60 Hz - galvanic isolation 2,5KV

    Power consumption

    9 Watt/VA  

    8 Watt/VA

    Display

    Display 4 digits 0,52" white + Display 5 digits 0,3" red

    Display 4 digits 0,52" white + Display 5 digits 0,3" red

    Analogue inputs

    1x Ris. 16bit, programmable for thermocouples K, J, S, R ,T, E,N, B (automatic compensation of cold junction -25...85°C, accuracy @25°C ±0,2% F.S. ±1 digit F.S.), Thermoresistances PT100, PT500, PT1000, Ni100, PTC1K, NTC10K (B 3435K), Process signals 0-20/4..20mA, 0-1/0-5/0-10V; 0..60mV, Potentiometers F.S. 1....150Kohm

    1x Ris. 16bit, programmable for thermocouples K, J, S, R ,T, E,N, B (automatic compensation of cold junction -25...85°C, accuracy @25°C ±0,2% F.S. ±1 digit F.S.), Thermoresistances PT100, PT500, PT1000, Ni100, PTC1K, NTC10K (B 3435K), Process signals 0-20/4..20mA, 0-1/0-5/0-10V; 0..60mV, Potentiometers F.S. 1....150Kohm: Current transformer 50mA

    Digital inputs

    2 PNP

    2 PNP

    Digital outputs

    2 x PNP 12VDC - 25mA o 24VDC - 15mA selectable by parameter

    2 x PNP 12VDC - 25mA o 24VDC - 15mA selectable by parameter

    Relay outputs

    2 x (2 A - 250 V AC resistive load)

    3 x (2 A - 250 V AC resistive load)

    Analogue outputs

    1 x 4..20 mA (40000 points ± 0,2% F.S ) o 0..10 V DC (40000 points ± 0,2% F.S.)

    1 x 4..20 mA (40000 points ± 0,2% F.S ) o 0..10 V DC (40000 points ± 0,2% F.S.)

    Serial communication

    RS485 (1200..115200 Baud) galvanically isolated

    • Cycles / Profiles
      up to 15
    • Steps/Segments
      up to 30 for each cycle ( max duration per step 99.59 hh.mm)
    • Control algorithms
      ON - OFF with hysteresis, P., P.I., P.I.D., P.D. time proportional
    • Tuning
      Manual or automatic
    • Alarm mode
      Absolute / Threshold, Band, High / Low deviation. Alarm with optional Manual reset. Loop Break Alarm
    • Dual P.I.D.
      Heating / Cooling with dual P.I.D.
    • Open / Close logics
      Open / Close logics for motorized valves command
    • Software parameter configuration
      Software MyPixsysLab, App MyPixsys
    • Data protection
      Lock of cycles - Access to parameters by Password
    • ATR264-12ABC-T
      PROGRAMMER/TEMP. CONTR. 15 CYCLES 48x48 4+5 Digit 1AI-1AO-2DI/O-2RL-RS485
      link locator link pixsys link shop
    • ATR264-13ABC
      PROGRAMMER/TEMP. CONTR. 15 CYCLES 48x48 4+5 Digit 1AI-1AO-2DI- 2 DO-3RL-CT INP.
      link locator link pixsys link shop
    pixsys

    Via Po, 16
    30030 - Mellaredo di Pianiga (VE)
    Italy
    Ph. +39 041 5190518 
    Mail: info@pixsys.net

    • COMPANY

      • About us
      • News
      • Applications
    • SUPPORT

      • Real time support
      • Technical FORUM
      • Video tutorials
    Privacy Policy Contacts
    REA PD 362721 - VAT no. IT04111740280 - Suppliers PEC: pixsyssrl_fornitori@pec.it
    Copyright © Pixsys 2025. All Rights Reserved.
    Back to top
    Iris _